D-shape CAT6A panel connector, shielded, IDC termination, nickel housing
Attention! Does not intermate with CAT6 cable connector NE8MC6-MO and NKE6S* cables.
Product | |
Title | NE8FDX-Y6 |
Gender | female |
Electrical | |
Dielectric strength | 1 kVdc |
Insulation resistance | > 0.5 GΩ |
Rated current per contact | 1.5 A |
Rated voltage | ≤ 57 V |
Transmission performance | CAT6A acc. to TIA/EIA 568C channel specifications CLASS EA acc. to ISO/IEC 11801 channel specifications |
Power over Ethernet | PoE type 3 class 6 (60W) acc. IEEE 802.3bt |
Mechanical | |
Lifetime | > 1000 mating cycles |
Wiresize | |
Wiresize | solid: AWG 26/1 - AWG 22/1 stranded: AWG 26/7 - AWG 22/7 |
Locking device | Latch lock |
Mounting direction | Front mounting |
Insulation diameter | 0.85 - 1.6 mm |
Material | |
Contact plating | Au |
Shell | Zinc diecast (ZnAl4Cu1) |
Shell plating | Nickel |
Environmental | |
Flammability | UL 94 V-0 EN 45545 R26 |
Temperature range | -40 °C to + 70 °C |
Standard compliance | ISO/IEC 11801-1 Ed. 1.0 (2017-11) IEC 60603-7-3 Ed.2.0 (2010-04) IEC 60512-99-002 Ed.2.0 (2022-01) IEC 60512-9-3 (2011-06) EN 45545-2:2020+A1:2023 (R26, clause 4.2, clause 4.3.2) |